Thin Film Solar Panels in 2026:
CIGS, CdTe and a-Si Explained

Updated November 15, 2026

"Thin film" gets used for two very different products. One is the large glass CdTe module that covers solar farms. The other is the bendable CIGS panel stuck to an RV roof or a boat canopy. They share a principle, a light-absorbing layer far thinner than a silicon wafer, and very little else. This page sorts out the types, compares them with flexible silicon panels and explains when thin film is the right buy.

The short version

  • Thin film means the active layer is deposited as a thin coating instead of being cut from a silicon wafer. It does not automatically mean flexible.
  • CdTe is the big commercial thin film: rigid glass modules for utility and commercial projects, with module efficiency above 19% according to the Department of Energy.
  • CIGS is the thin film you can bend. It is the material behind most truly rollable panels for RVs and boats, at lower efficiency than flexible silicon.
  • Amorphous silicon is the least efficient type. Perovskites are promising but not yet manufactured at scale.

What makes a solar panel "thin film"

Matte dark thin-film solar panel partly rolled up on a teak boat deck

A standard panel is built from crystalline silicon wafers, sliced from a solid ingot and wired together. A thin-film panel is made differently: the semiconductor is deposited as a thin layer onto a backing such as glass, metal foil or plastic. That changes what the panel can be. On glass, it is a rigid module that looks much like any other. On a flexible backing, it can roll and bend far more than a wafer-based panel, because there is no brittle wafer to crack.

Note that most "flexible solar panels" sold today are not thin film at all. They are crystalline silicon cells laminated in polymer instead of glass. We cover those in our guide to the best flexible solar panels.

Types of thin film solar panels compared

Efficiency figures come from the U.S. Department of Energy where available, and from the maker's spec sheet for specific products. Lab records and commercial modules are very different numbers, so the table keeps them apart.

TypeEfficiencyFlexible?Where you see itKeep in mind
CdTe (cadmium telluride)Modules above 19% (DOE, 2024)No, built on glassUtility-scale and commercial arraysSecond most common PV technology after silicon; 21% of the U.S. market in 2022 (DOE)
CIGS (copper indium gallium selenide)Commercial modules typically 12-14%, lab cells above 20% (DOE); BougeRV Yuma rated 17% cellYes, on flexible backingsRollable RV, van and marine panelsLarger and pricier per watt than flexible silicon
a-Si (amorphous silicon)About 7% for modules in a 2007 NREL reportYesOlder and specialty flexible panelsLowest efficiency of the group, so it needs the most area
PerovskiteOver 26% on small lab cells; almost 34% in perovskite-silicon tandems (DOE)Not in commercial products yetLabs and pilot linesNot yet made at scale; stability is a main challenge (DOE)
Flexible crystalline silicon (for comparison)About 25% cell for N-type and back-contact models (maker specs)Semi-flexible, bends in one directionMost flexible panels for RVs and boatsCells can micro-crack if flexed repeatedly or stepped on

CdTe: the thin film on solar farms

Cadmium telluride is by far the most commercially important thin film. The Department of Energy calls it the second most common PV technology after crystalline silicon, with 21% of the U.S. market and 4% of the global market in 2022. It also notes that CdTe modules can be made in under 4.5 hours, and that over 90% of a decommissioned module can be recycled.

First Solar, the best-known CdTe manufacturer, sells its Series 6 and Series 7 modules for utility-scale and distributed generation projects. These are full-size glass modules; distributor listings show open-circuit voltages around 220V for Series 6 and 7 models. They are not panels for a 12V camper system. If you see "thin film" on a 400W+ glass panel, this is almost always what it is.

CIGS: the thin film you can bend

CIGS is the material behind most panels that really roll. Because it is deposited as a film rather than cut from a wafer, a CIGS panel can bend much further than a silicon one without cracking cells. The BougeRV Yuma 200W is a good example of what that means in practice: BougeRV lists it at 17% cell efficiency, 5.95 lb, 0.06 inches thick and 360° flexible, and says it is safe to walk on. It comes with a 10-year product and 25-year performance warranty.

The trade-off is area and price. Compare it with a 200W N-type flexible silicon panel from the same maker, the BougeRV Arch Pro:

Spec (maker data)Yuma 200W CIGSArch Pro 200W N-type silicon
Cell efficiency17%25%
Size82.8 × 27.1 in (about 2,244 sq in)53 × 31 in (about 1,643 sq in)
Weight5.95 lb7.9 lb
Flexibility360°, rollableUp to 270°
WalkableYes, per BougeRVNot stated
Pmax temperature coefficient-0.38%/°C-0.35%/K
Warranty10 yr product, 25 yr performance5 yr materials, 25 yr 80% output
Maker's price, Nov 2026About $380-400About $245-257

For the same 200W, the CIGS panel needs about 37% more surface (2,244 ÷ 1,643) and costs more, but it is lighter, thinner, rated walkable and bends further. Note one thing the spec sheets show that the marketing does not: BougeRV describes CIGS as better at high temperatures, yet its own listed temperature coefficient for the Yuma (-0.38%/°C) is slightly worse than the Arch Pro's (-0.35%/K). BougeRV also advises against connecting CIGS and monocrystalline panels to the same controller input, because their voltages differ too much.

Amorphous silicon and perovskites

Amorphous silicon (a-Si) is still used in some flexible and specialty panels. Its weakness is efficiency: a 2007 NREL report put a-Si-based modules at about 7%, so it needs far more area than any other option here for the same output.

Perovskites are the thin film everyone is watching. The Department of Energy reports small-area lab cells above 26% and perovskite-silicon tandem cells at almost 34%, but also says perovskite PV is not yet manufactured at scale and that stability and durability are among the main challenges. If you are buying a panel for a roof or a boat in 2026, perovskites are not yet a practical choice.

When thin film makes sense

  • Tight curves and soft surfaces. Rounded trailer roofs, boat canopies and bimini tops, where a silicon panel would have to flex more than it should. Our guide to flexible marine solar panels covers boat mounting in detail.
  • Foot traffic. Decks and roofs people walk on, if the maker rates the panel as walkable.
  • Weight-sensitive installs where a pound matters more than a square foot.
  • Large ground-mount or commercial projects, where CdTe glass modules compete directly with silicon.

Where it doesn't: a short van roof or a crowded RV roof where you need the most watts from limited space. There, N-type or back-contact flexible silicon gets more power from the same area. See our guide to flexible solar panels for RVs and vans for current models and sizing.

FAQ

Are thin film solar panels good?

They are good at specific jobs. CdTe glass modules are a mainstream choice for utility-scale and large commercial projects. Flexible CIGS panels suit curved RV and boat surfaces and places where people may step on the panel. For a small roof where every square foot counts, high-efficiency crystalline silicon usually gives more power for the money.

Are all thin film solar panels flexible?

No. Thin film describes the thickness of the light-absorbing layer, not the panel. CdTe modules are built on glass and are as rigid as standard panels. CIGS and amorphous silicon can be deposited on flexible backings, which is why most bendable thin-film panels use them.

How efficient are thin film solar panels?

It depends on the material. The U.S. Department of Energy reports CdTe modules above 19% and commercial CIGS modules typically at 12-14%. A flexible CIGS panel such as the BougeRV Yuma is rated at 17% cell efficiency, while the best flexible silicon panels are rated around 25%.

Is perovskite a thin film?

Yes. The Department of Energy describes perovskite cells as thin-film because they need much thinner active layers. Small lab cells have passed 26% efficiency, but perovskite PV is not yet manufactured at scale and durability is still one of the main open problems.